Send Message

OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502

Basic Information
Place of Origin: CHINA
Brand Name: DONGJIAXIN
Certification: ISO
Model Number: YJV22 8.7/15KV
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: 100 meters per roll or according to the customer's request.
Delivery Time: 7-15 working days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 100KM/WEEK
Model Name: Medium Voltage Cable Conductor Type: OFC Copper Conductor
Sheath: PVC Insulation: XLPE
Standard: IEC 60502-2 Applicaiton: Industrial Installations, Infrastructures, Distribution Networks, Etc
High Light:

15KV fire rated power cable

,

OFC single core power cable

,

8.7KV single core power cable

IEC 60502 Single Core Power Cable , 8.7/15 KV XLPE Insulated Power Cable Medium Voltage

1. Construction

Conductor Plain annealed copper wire,solid, Class 1,strand, Class 2,
meets to GB/T 3956, IEC 60228,BS 6360.
Conductor Screen Semi-conductor (MV only)
Insulation XLPE
Insulation Screen Semi-conductor (MV only)
Metallic Screen Copper tape
Filler PP Yarn, or Paper
Separator Binding tape
Inner sheath Extruded PVC (MV only)
Armouring Steel Tape Armoured (STA)
Sheath PVC(LSZH)

 

2. Technical parameters

ross section of conductor(mm²) Conductor structure Insulation thickness(mm) sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×35 7 4.5 2.6 51.3 0.524
3×50 10 4.5 2.7 53.8 0.387
3×70 14 4.5 2.8 57.5 0.268
3×95 19 4.5 3.0 62.0 0.193
3×120 24 4.5 3.1 65.2 0.153
3×150 30 4.5 3.2 68.3 0.124
3×185 37 4.5 3.3 72.3 0.0991

 

3. Characteristics

  • Rated voltage: 1.8/3kV, 6/10kV, 8.7/10kV, 8.7/15kV, 12/20kV, 21/35kV, 26/35kV
  • Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.
  • Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position
  • Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables
  • 15 x cable O.D for single-core armoured cables
  • 15 x cable O.D for multi-core non-armoured cables
  • 12 x cable O.D for multi-core armoured cables

 

4. Application

Medium voltage cables for distribution networks; also for connection to generation units and plant and process connection. For installation in ground,in water outdoors, indoors and in cable ducts for power stations, industry, and distribution networks. The water blocking tape avoids propagation inside the cable.

 

OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 0

▼ Cable Drum Data:

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Four Core LV power cable XLPE Insulated steel tape armoured Electrical Cable 4 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300
 

 

▼ Delivery Port :

OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 2 OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 3 OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 4
Port of Shenzhen Port of Hongkong

Port of Guangzhou

▼ CNAS Labortory :

3S Safety Cable Advanced Institute of Technology with 7 laboratories, has been established in Finecredit Group,

including Electrical Performance Laboratory, Mechanical Performance Laboratory, Combustion Test Laboratory,

High Frequency Laboratory, etc. Equipped with over 50 advanced equipment and technologies.

OFC Fire Rated Power Cable , 8.7-15KV Single Core Power Cable IEC 60502 5

Contact Details
Coco

Phone Number : +8613528796850

WhatsApp : +8613528796850