Model Name: | YJV22 | Rated Voltage: | 0.6/1KV |
---|---|---|---|
Size: | 1.5~630mm² | Nos.of Core: | 2~5 |
Conductor Type: | Stranded Annealed Copper Class 2 | Sheath: | PVC |
Application: | Industrial Manufacturing, Shopping Malls, Convention And Exhibition Centers, Architectural Buildings | Warranty: | 12 Months |
High Light: | 34.5kv 3 core electrical wire,3Core 240mm2 6.6 kv power cable,6.6 kv power cable |
Power Cable 3 Core 300mm2 500mm2 3x240mm Yjv / Yjv22 Cu Underground 240 mm2 Pvc Single Core Power 6.6kv 34.5kv Xlpe
▼ Application:
The armored cable mechanical protection layer can be added to the cable of any structure to increase the mechanical strength of the cable and improve the corrosion resistance. It is a wire and cable designed for areas that are prone to mechanical damage and extremely susceptible to erosion. It can be laid in any way, and is more suitable for direct burial laying in rocky areas.
▼ Constraction:
Core Conductor | annealed copper (stranded core) |
Popular sizes | 2~5 core x1.5~630mm² |
Cable conductor | stranded annealed copper |
Insulation | XLPE |
Jacket | PVC Jacket Power Cable with Steel Tape Armored |
Temperature rating | -25C up to +90℃ |
Voltage suitable | 0.6/1kV |
Fire performance | IEC 60332-1 |
Armored | Double Steal Tape |
▼ Advantage:
Armored cables are generally fixedly laid power cables. Generally speaking, they are fixed in one place and basically do not move. The power line transmits electric energy.
In addition to the above, the purpose of adding the armor layer to the cable can also enhance mechanical protection such as tensile strength and compressive strength to extend the service life.
The armor has a certain degree of resistance to external forces, and it can also prevent rats from biting, and will not cause power transmission problems through the armor. The bending radius of the armor should be large, and the armor layer can be grounded to protect the cable.
▼ Technical parameters:
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Strip thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
3×2.5+1×1.5 | 1 | 0.7 | 0.2 | 1.8 | 13.2 | 7.41 |
3×4+1×2.5 | 1 | 0.7 | 0.2 | 1.8 | 14.3 | 4.61 |
3×6+1×4 | 1 | 0.7 | 0.2 | 1.8 | 15.4 | 3.08 |
3×10+1×6 | 7 | 0.7 | 0.2 | 1.8 | 17.6 | 1.83 |
3×16+1×10 | 7 | 0.7 | 0.2 | 1.8 | 20.1 | 1.15 |
3×25+1×16 | 7 | 0.9 | 0.2 | 1.8 | 23.6 | 0.727 |
3×35+1×16 | 7 | 0.9 | 0.2 | 1.8 | 25.4 | 0.524 |
3×50+1×25 | 10 | 1.0 | 0.2 | 1.9 | 29.0 | 0.387 |
3×70+1×35 | 14 | 1.1 | 0.2 | 2.0 | 32.8 | 0.268 |
3×95+1×50 | 19 | 1.1 | 0.5 | 2.2 | 39.4 | 0.193 |
3×120+1×70 | 24 | 1.2 | 0.5 | 2.3 | 43.8 | 0.153 |
3×150+1×70 | 30 | 1.4 | 0.5 | 2.5 | 47.3 | 0.124 |
3×185+1×95 | 37 | 1.6 | 0.5 | 2.6 | 53.8 | 0.0991 |
3×240+1×120 | 48 | 1.7 | 0.5 | 2.8 | 59.6 | 0.0754 |
3×300+1×150 | 61 | 1.8 | 0.5 | 3.0 | 65.2 | 0.0601 |
3×400+1×185 | 61 | 2.0 | 0.5 | 3.3 | 72.9 | 0.0470 |
3×500+1×240 | 61 | 2.2 | 0.8 | 3.6 | 82.3 | 0.0366 |
3×630+1×300 | 61 | 2.4 | 0.8 | 3.9 | 96.3 | 0.0283 |
3×2.5+2×1.5 | 1 | 0.7 | 0.2 | 1.8 | 13.9 | 7.41 |
3×4+2×2.5 | 1 | 0.7 | 0.2 | 1.8 | 15.1 | 4.61 |
3×6+2×4 | 1 | 0.7 | 0.2 | 1.8 | 16.3 | 3.08 |
3×10+2×6 | 7 | 0.7 | 0.2 | 1.8 | 18.6 | 1.83 |
3×16+2×10 | 7 | 0.7 | 0.2 | 1.8 | 21.3 | 1.15 |
3×25+2×16 | 7 | 0.9 | 0.2 | 1.8 | 25.0 | 0.727 |
3×35+2×16 | 7 | 0.9 | 0.2 | 1.8 | 26.6 | 0.524 |
3×50+2×25 | 10 | 1.0 | 0.2 | 2.0 | 30.7 | 0.387 |
3×70+2×35 | 14 | 1.1 | 0.5 | 2.1 | 36.7 | 0.268 |
3×95+2×50 | 19 | 1.1 | 0.5 | 2.3 | 41.7 | 0.193 |
3×120+2×70 | 24 | 1.2 | 0.5 | 2.4 | 46.6 | 0.153 |
3×150+2×70 | 30 | 1.4 | 0.5 | 2.5 | 49.5 | 0.124 |
3×185+2×95 | 37 | 1.6 | 0.5 | 2.7 | 56.5 | 0.0991 |
3×240+2×120 | 48 | 1.7 | 0.5 | 2.9 | 62.9 | 0.0754 |
3×300+2×150 | 61 | 1.8 | 0.5 | 3.1 | 68.9 | 0.0601 |
3×400+2×185 | 61 | 2.0 | 0.5 | 3.4 | 76.7 | 0.0470 |
3×500+2×240 | 61 | 2.2 | 0.8 | 3.7 | 86.9 | 0.0366 |
3×630+2×300 | 61 | 2.4 | 0.8 | 4.0 | 100.5 | 0.0283 |
4×2.5+1×1.5 | 1 | 0.7 | 0.2 | 1.8 | 14.1 | 7.41 |
4×4+1×2.5 | 1 | 0.7 | 0.2 | 1.8 | 15.3 | 4.61 |
4×6+1×4 | 1 | 0.7 | 0.2 | 1.8 | 16.6 | 3.08 |
4×10+1×6 | 7 | 0.7 | 0.2 | 1.8 | 19.2 | 1.83 |
4×16+1×10 | 7 | 0.7 | 0.2 | 1.8 | 21.9 | 1.15 |
4×25+1×16 | 7 | 0.9 | 0.2 | 1.8 | 25.9 | 0.727 |
4×35+1×16 | 7 | 0.9 | 0.2 | 1.9 | 28.2 | 0.524 |
4×50+1×25 | 10 | 1.0 | 0.2 | 2.0 | 32.0 | 0.387 |
4×70+1×35 | 14 | 1.1 | 0.5 | 2.2 | 38.6 | 0.268 |
4×95+1×50 | 19 | 1.1 | 0.5 | 2.3 | 43.7 | 0.193 |
4×120+1×70 | 24 | 1.2 | 0.5 | 2.5 | 48.8 | 0.153 |
4×150+1×70 | 30 | 1.4 | 0.5 | 2.6 | 53.8 | 0.124 |
4×185+1×95 | 37 | 1.6 | 0.5 | 2.8 | 59.8 | 0.0991 |
4×240+1×120 | 48 | 1.7 | 0.5 | 3.0 | 66.5 | 0.0754 |
4×300+1×150 | 61 | 1.8 | 0.5 | 3.3 | 73.1 | 0.0601 |
4×400+1×185 | 61 | 2.0 | 0.8 | 3.6 | 82.7 | 0.0470 |
4×500+1×240 | 61 | 2.2 | 0.8 | 3.9 | 92.2 | 0.0366 |
4×630+1×300 | 61 | 2.4 | 0.8 | 4.2 | 103.3 | 0.0283 |
▼ Delivery Port :
Port of Shenzhen | Port of Hongkong |
Port of Guangzhou |
▼ CNAS Labortory
3S Safety Cable Advanced Institute of Technology with 7 laboratories, has been established in Finecredit Group,
including Electrical Performance Laboratory, Mechanical Performance Laboratory, Combustion Test Laboratory,
High Frequency Laboratory, etc. Equipped with over 50 advanced equipment and technologies.
▼ Payment:
We usually use T/T
T/T deposit before production and balance when shipment.
Payment terms: Western Union, Escrow, Paypal, T/T, L/C