Send Message

Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable

Basic Information
Place of Origin: CHINA
Brand Name: DONGJIAXIN
Certification: QS
Model Number: YJV22
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Steel wooden drum
Delivery Time: 7-15 working days
Payment Terms: L/C, T/T
Supply Ability: 100KM/Week
Model Name: YJV22 Rated Voltage: 0.6/1KV
Size: 1.5~630mm² Nos.of Core: 2~5
Conductor Type: Stranded Annealed Copper Class 2 Sheath: PVC
Application: Industrial Manufacturing, Shopping Malls, Convention And Exhibition Centers, Architectural Buildings Warranty: 12 Months
High Light:

34.5kv 3 core electrical wire

,

3Core 240mm2 6.6 kv power cable

,

6.6 kv power cable

Power Cable 3 Core 300mm2 500mm2 3x240mm Yjv / Yjv22 Cu Underground 240 mm2 Pvc Single Core Power 6.6kv 34.5kv Xlpe 

 

Application:

The armored cable mechanical protection layer can be added to the cable of any structure to increase the mechanical strength of the cable and improve the corrosion resistance. It is a wire and cable designed for areas that are prone to mechanical damage and extremely susceptible to erosion. It can be laid in any way, and is more suitable for direct burial laying in rocky areas.

Constraction:

Core Conductor annealed copper (stranded core)
Popular sizes 2~5 core x1.5~630mm²
Cable conductor stranded annealed copper
Insulation XLPE
Jacket PVC Jacket Power Cable with Steel Tape Armored
Temperature rating -25C up to +90℃
Voltage suitable 0.6/1kV
Fire performance IEC 60332-1
Armored  Double Steal Tape

Advantage:

Armored cables are generally fixedly laid power cables. Generally speaking, they are fixed in one place and basically do not move. The power line transmits electric energy.

In addition to the above, the purpose of adding the armor layer to the cable can also enhance mechanical protection such as tensile strength and compressive strength to extend the service life.

The armor has a certain degree of resistance to external forces, and it can also prevent rats from biting, and will not cause power transmission problems through the armor. The bending radius of the armor should be large, and the armor layer can be grounded to protect the cable.

Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable 0

▼ Technical parameters:

 

Cross section of conductor(mm²) Conductor structure Insulation Thickness(mm) Strip thickness(mm) Copper sheath thickness(mm) Approx.cable diameter(mm) Max resistance of conductor at 20℃ (Ω/km)
3×2.5+1×1.5 1 0.7 0.2 1.8 13.2 7.41
3×4+1×2.5 1 0.7 0.2 1.8 14.3 4.61
3×6+1×4 1 0.7 0.2 1.8 15.4 3.08
3×10+1×6 7 0.7 0.2 1.8 17.6 1.83
3×16+1×10 7 0.7 0.2 1.8 20.1 1.15
3×25+1×16 7 0.9 0.2 1.8 23.6 0.727
3×35+1×16 7 0.9 0.2 1.8 25.4 0.524
3×50+1×25 10 1.0 0.2 1.9 29.0 0.387
3×70+1×35 14 1.1 0.2 2.0 32.8 0.268
3×95+1×50 19 1.1 0.5 2.2 39.4 0.193
3×120+1×70 24 1.2 0.5 2.3 43.8 0.153
3×150+1×70 30 1.4 0.5 2.5 47.3 0.124
3×185+1×95 37 1.6 0.5 2.6 53.8 0.0991
3×240+1×120 48 1.7 0.5 2.8 59.6 0.0754
3×300+1×150 61 1.8 0.5 3.0 65.2 0.0601
3×400+1×185 61 2.0 0.5 3.3 72.9 0.0470
3×500+1×240 61 2.2 0.8 3.6 82.3 0.0366
3×630+1×300 61 2.4 0.8 3.9 96.3 0.0283
3×2.5+2×1.5 1 0.7 0.2 1.8 13.9 7.41
3×4+2×2.5 1 0.7 0.2 1.8 15.1 4.61
3×6+2×4 1 0.7 0.2 1.8 16.3 3.08
3×10+2×6 7 0.7 0.2 1.8 18.6 1.83
3×16+2×10 7 0.7 0.2 1.8 21.3 1.15
3×25+2×16 7 0.9 0.2 1.8 25.0 0.727
3×35+2×16 7 0.9 0.2 1.8 26.6 0.524
3×50+2×25 10 1.0 0.2 2.0 30.7 0.387
3×70+2×35 14 1.1 0.5 2.1 36.7 0.268
3×95+2×50 19 1.1 0.5 2.3 41.7 0.193
3×120+2×70 24 1.2 0.5 2.4 46.6 0.153
3×150+2×70 30 1.4 0.5 2.5 49.5 0.124
3×185+2×95 37 1.6 0.5 2.7 56.5 0.0991
3×240+2×120 48 1.7 0.5 2.9 62.9 0.0754
3×300+2×150 61 1.8 0.5 3.1 68.9 0.0601
3×400+2×185 61 2.0 0.5 3.4 76.7 0.0470
3×500+2×240 61 2.2 0.8 3.7 86.9 0.0366
3×630+2×300 61 2.4 0.8 4.0 100.5 0.0283
4×2.5+1×1.5 1 0.7 0.2 1.8 14.1 7.41
4×4+1×2.5 1 0.7 0.2 1.8 15.3 4.61
4×6+1×4 1 0.7 0.2 1.8 16.6 3.08
4×10+1×6 7 0.7 0.2 1.8 19.2 1.83
4×16+1×10 7 0.7 0.2 1.8 21.9 1.15
4×25+1×16 7 0.9 0.2 1.8 25.9 0.727
4×35+1×16 7 0.9 0.2 1.9 28.2 0.524
4×50+1×25 10 1.0 0.2 2.0 32.0 0.387
4×70+1×35 14 1.1 0.5 2.2 38.6 0.268
4×95+1×50 19 1.1 0.5 2.3 43.7 0.193
4×120+1×70 24 1.2 0.5 2.5 48.8 0.153
4×150+1×70 30 1.4 0.5 2.6 53.8 0.124
4×185+1×95 37 1.6 0.5 2.8 59.8 0.0991
4×240+1×120 48 1.7 0.5 3.0 66.5 0.0754
4×300+1×150 61 1.8 0.5 3.3 73.1 0.0601
4×400+1×185 61 2.0 0.8 3.6 82.7 0.0470
4×500+1×240 61 2.2 0.8 3.9 92.2 0.0366
4×630+1×300 61 2.4 0.8 4.2 103.3 0.0283

▼ Delivery Port :

Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable 1 Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable 2 Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable 3
Port of Shenzhen Port of Hongkong

Port of Guangzhou

 

▼ CNAS Labortory

3S Safety Cable Advanced Institute of Technology with 7 laboratories, has been established in Finecredit Group,

including Electrical Performance Laboratory, Mechanical Performance Laboratory, Combustion Test Laboratory,

High Frequency Laboratory, etc. Equipped with over 50 advanced equipment and technologies.

Underground 3 Core Electrical Wire , 240mm2 24kv 6.6 Kv N2XRY STA Power Cable 4

▼ Payment:

We usually use T/T

T/T deposit before production and balance when shipment.

Payment terms: Western Union, Escrow, Paypal, T/T, L/C

 

Contact Details
Coco

Phone Number : +8613528796850

WhatsApp : +8613528796850