Place of Origin: | CHINA |
---|---|
Brand Name: | DONGJIAXIN |
Certification: | IEC, Rosh,CCC |
Model Number: | DWZA-YJY/N2X2Y |
Minimum Order Quantity: | Negotiable |
Price: | Negotiable |
Packaging Details: | Steel wooden drum, Coil In Foil / Drum |
Delivery Time: | 7-15 working days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100KM/Week |
Model Name: | DWZA | Armour: | Galvanized Steel Tape |
---|---|---|---|
Popular Sizes: | 2~5core X1.5~630mm² | Insulator: | XLPE |
Conductor Type: | Bare Copper Class 2 | Sheath: | ZR-PVC, PE, LSOH,etc. |
Application: | Underground | ||
High Light: | N2x2y Low Smoke Halogen Free Cable,Halogen Free 10mm2 Cable,CCC Approved Halogen Free Cable |
About Dongjiaxin
Shenzhen Dongjiaxin is a top original cable manufacturer and standard cable brand for 32 years with annual sales 1 Billion US Dollars. We use finest raw material, most advanced processes and quality management system, to ensure all cables are produced with highest international quality standard and subjected to the most stringent tests in Dongjiaxin CNAS accredited laboratories.
Dongjiaxin cable is far superior than any other brand, when compete with Prysmian Nexans our price more competitive, safe, reliable, durable. Dongjiaxin work with 10+ world fortune 500 companies, listed companies and export to different countries. Join in Dongjiaxin to enjoy cables beyond perfection.
Shenzhen Dongjiaxin Cable include: Electrical wire, Power cable, Control Cable, Solar Cable, Industrial Electrical Cable, Ethernet Cable, Rubber Cable and more. With R&D on new material and technology, Dongjiaxin Cable keeps continuous improvement on its performance and replace imported brand, and become the preferable brand for large scale government projects, engineering projects and contruction, transport, industrial customers.
Dongjiaxin qualification: ISO9001,ISO14001,ISO45001,TS16949,ISO17025,iLac,CNAS,TUV,VDE,ETL,IEC,UL,CE,RoHS,Reach,CB,CCC,CQC.
Product Features
1. Durable: LSZH Sheath ensures superior protection and longevity.
2. Safe: 10mm2 Low Smoke Halogen Free Cable means no toxic fumes.
3. Reliable: N2X2Y Class 2 Conductor ensures maximum dependability.
4. Flexible: 10mm2 cable is easy to install and route.
5. Efficient: LSZH Sheath helps reduce energy loss.
This LSZH Sheath 10mm2 Low Smoke Halogen Free Cable N2X2Y Class 2 Conductor is perfect for your needs! With its halogen-free design and low smoke emission, it is the perfect choice for any environment that requires a safe and reliable cable. The 10mm2 conductor provides excellent current-carrying capacity and its LSZH sheath provides superior fire-resistance and protection against mechanical damage. The Class 2 conductor ensures maximum electrical safety and the N2X2Y construction provides superior flexibility. This cable is the perfect choice for any application that requires a reliable and safe cable.
copper conductor pvc insulated steel tape armoured multi-core power cablesConstruction: 1. Conductor : Circular compact stranded annealed copper
Application:
Technical data:
IEC 60502, 60332, 60331 DIN VDE 0276-620
Model Explanation:
Product details
XLPE Insulation Electric Wire Cable
|
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.
▼ Cable Drum Data:
CABLE DRUMS | D1=Flange Diameter(mm) | W=Useful Width (mm) | D2=Barrel Diameter(mm) |
1000 | 700 | 500 | |
1100 | 700 | 550 | |
1200 | 700 | 600 | |
1400 | 750 | 710 | |
1600 | 900 | 900 | |
1800 | 1120 | 1000 | |
2400 | 1150 | 1300 |
▼ Delivery Port :
Port of Shenzhen | Port of Hongkong |
Port of Guangzhou
|
▼ Technical parameters:
1. Single Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
1×1.5 | 1 | 0.7 | 1.4 | 6.0 | 12.1 |
1×2.5 | 1 | 0.7 | 1.4 | 6.4 | 7.41 |
1×4 | 1 | 0.7 | 1.4 | 6.9 | 4.61 |
1×6 | 1 | 0.7 | 1.4 | 7.3 | 3.08 |
1×10 | 7 | 0.7 | 1.4 | 8.4 | 1.83 |
1×16 | 7 | 0.7 | 1.4 | 9.4 | 1.15 |
1×25 | 7 | 0.9 | 1.4 | 11.0 | 0.727 |
1×35 | 7 | 0.9 | 1.4 | 12.0 | 0.524 |
1×50 | 10 | 1.0 | 1.4 | 13.3 | 0.387 |
1×70 | 14 | 1.1 | 1.4 | 15.1 | 0.268 |
1×95 | 19 | 1.1 | 1.5 | 17.3 | 0.193 |
1×120 | 24 | 1.2 | 1.5 | 19.0 | 0.153 |
1×150 | 30 | 1.4 | 1.6 | 20.9 | 0.124 |
1×185 | 37 | 1.6 | 1.6 | 23.0 | 0.0991 |
1×240 | 48 | 1.7 | 1.7 | 25.7 | 0.0754 |
1×300 | 61 | 1.8 | 1.8 | 28.3 | 0.0601 |
1×400 | 61 | 2.0 | 1.9 | 31.6 | 0.0470 |
1×500 | 61 | 2.2 | 2.0 | 35.1 | 0.0366 |
1×630 | 61 | 2.4 | 2.2 | 42.1 | 0.0283 |
2. 2 Core&3 Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
2×1.5 | 1 | 0.7 | 1.8 | 10.6 | 12.1 |
2×2.5 | 1 | 0.7 | 1.8 | 11.4 | 7.41 |
2×4 | 1 | 0.7 | 1.8 | 12.4 | 4.61 |
2×6 | 1 | 0.7 | 1.8 | 13.2 | 3.08 |
2×10 | 7 | 0.7 | 1.8 | 15.4 | 1.83 |
2×16 | 7 | 0.7 | 1.8 | 17.4 | 1.15 |
2×25 | 7 | 0.9 | 1.8 | 20.6 | 0.727 |
2×35 | 7 | 0.9 | 1.8 | 22.6 | 0.524 |
2×50 | 10 | 1.0 | 1.8 | 26.2 | 0.387 |
2×70 | 14 | 1.1 | 1.8 | 29.8 | 0.268 |
2×95 | 19 | 1.1 | 1.9 | 34.0 | 0.193 |
2×120 | 24 | 1.2 | 2.0 | 37.4 | 0.153 |
2×150 | 30 | 1.4 | 2.2 | 41.2 | 0.124 |
2×185 | 37 | 1.6 | 2.3 | 45.6 | 0.0991 |
2×240 | 48 | 1.7 | 2.5 | 51.0 | 0.0754 |
2×300 | 61 | 1.8 | 2.6 | 56.0 | 0.0601 |
2×400 | 61 | 2.0 | 2.9 | 62.6 | 0.0470 |
2×500 | 61 | 2.2 | 3.1 | 70.0 | 0.0366 |
2×630 | 61 | 2.4 | 3.3 | 83.6 | 0.0283 |
3×1.5 | 1 | 0.7 | 1.8 | 11.2 | 12.1 |
3×2.5 | 1 | 0.7 | 1.8 | 12.1 | 7.41 |
3×4 | 1 | 0.7 | 1.8 | 13.2 | 4.61 |
3×6 | 1 | 0.7 | 1.8 | 14.0 | 3.08 |
3×10 | 7 | 0.7 | 1.8 | 16.4 | 1.83 |
3×16 | 7 | 0.7 | 1.8 | 18.6 | 1.15 |
3×25 | 7 | 0.9 | 1.8 | 22.0 | 0.727 |
3×35 | 7 | 0.9 | 1.8 | 24.2 | 0.524 |
3×50 | 10 | 1.0 | 1.8 | 28.0 | 0.387 |
3×70 | 14 | 1.1 | 1.9 | 32.1 | 0.268 |
3×95 | 19 | 1.1 | 2.0 | 36.4 | 0.193 |
3×120 | 24 | 1.2 | 2.1 | 40.3 | 0.153 |
3×150 | 30 | 1.4 | 2.3 | 44.3 | 0.124 |
3×185 | 37 | 1.6 | 2.4 | 49.1 | 0.0991 |
3×240 | 48 | 1.7 | 2.6 | 54.9 | 0.0754 |
3×300 | 61 | 1.8 | 2.7 | 60.1 | 0.0601 |
3×400 | 61 | 2.0 | 3.0 | 67.4 | 0.0470 |
3×500 | 61 | 2.2 | 3.2 | 75.3 | 0.0366 |
3×630 | 61 | 2.4 | 3.5 | 90.0 | 0.0283 |
3. 4 Core&5 Core
Cross section of conductor(mm²) | Conductor structure | Insulation thickness(mm) | sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
4×1.5 | 1 | 0.7 | 1.8 | 12.2 | 12.1 |
4×2.5 | 1 | 0.7 | 1.8 | 13.1 | 7.41 |
4×4 | 1 | 0.7 | 1.8 | 14.3 | 4.61 |
4×6 | 1 | 0.7 | 1.8 | 15.3 | 3.08 |
4×10 | 7 | 0.7 | 1.8 | 18.0 | 1.83 |
4×16 | 7 | 0.7 | 1.8 | 20.4 | 1.15 |
4×25 | 7 | 0.9 | 1.8 | 24.3 | 0.727 |
4×35 | 7 | 0.9 | 1.8 | 26.7 | 0.524 |
4×50 | 10 | 1.0 | 1.8 | 30.8 | 0.387 |
4×70 | 14 | 1.1 | 2.0 | 35.4 | 0.268 |
4×95 | 19 | 1.1 | 2.1 | 40.4 | 0.193 |
4×120 | 24 | 1.2 | 2.3 | 44.9 | 0.153 |
4×150 | 30 | 1.4 | 2.4 | 49.3 | 0.124 |
4×185 | 37 | 1.6 | 2.6 | 54.7 | 0.0991 |
4×240 | 48 | 1.7 | 2.8 | 61.0 | 0.0754 |
4×300 | 61 | 1.8 | 3.0 | 67.2 | 0.0601 |
4×400 | 61 | 2.0 | 3.3 | 75.3 | 0.0470 |
4×500 | 61 | 2.2 | 3.5 | 84.0 | 0.0366 |
4×630 | 61 | 2.4 | 3.8 | 100.5 | 0.0283 |
5×1.5 | 1 | 0.7 | 1.8 | 13.2 | 12.1 |
5×2.5 | 1 | 0.7 | 1.8 | 14.2 | 7.41 |
5×4 | 1 | 0.7 | 1.8 | 15.6 | 4.61 |
5×6 | 1 | 0.7 | 1.8 | 16.7 | 3.08 |
5×10 | 7 | 0.7 | 1.8 | 19.6 | 1.83 |
5×16 | 7 | 0.7 | 1.8 | 22.3 | 1.15 |
5×25 | 7 | 0.9 | 1.8 | 26.7 | 0.727 |
5×35 | 7 | 0.9 | 1.8 | 29.4 | 0.524 |
5×50 | 10 | 1.0 | 1.9 | 34.1 | 0.387 |
5×70 | 14 | 1.1 | 2.1 | 39.1 | 0.268 |
5×95 | 19 | 1.1 | 2.2 | 44.7 | 0.193 |
5×120 | 24 | 1.2 | 2.4 | 49.7 | 0.153 |
5×150 | 30 | 1.4 | 2.6 | 54.7 | 0.124 |
5×185 | 37 | 1.6 | 2.8 | 60.6 | 0.0991 |
5×240 | 48 | 1.7 | 3.0 | 67.7 | 0.0754 |
5×300 | 61 | 1.8 | 3.2 | 74.6 | 0.0601 |
5×400 | 61 | 2.0 | 3.5 | 83.4 | 0.0470 |
5×500 | 61 | 2.2 | 3.8 | 93.4 | 0.0366 |
5×630 | 61 | 2.4 | 4.1 | 111.7 | 0.0283 |
▼Ordering Advice:
Rated Voltage
Application Standard:IEC/BS/UL/GB
Number of Cores
Conductor Size $ Construction
Type of Insulation
Armored or unarmored. If armour, the armour type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement
If this all seems a little too technical for you, then why not get in touch with us.We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.