Model Name: | AAAC-ASTM B399 | Standards: | ASTM B399 |
---|---|---|---|
Conductor: | Bared | Conductor Material:: | Aluminum Clad Steel |
Conductor Type: | Stranded Annealed Copper Class 5 | Insulation: | XLPE/ PE/ PVC |
Application: | Overhead | ||
High Light: | 18.8m2 ASTM B399 Overhead Power Cables,18.8m2 XLPE Overhead Power Cables,ROHS aaac wire |
▼ Other special application cable can be provided upon requests:
Fire-resistant,Flame-retardant,Low-halogen,Non-halogen,Low-fume,Low-smoke ( LSZH ) ,as well as acid-alkali-proof,High temperature resistant,Termite and Rodent resistant, Water proof series and so on.
Standard 6201, 6101 aluminum alloy conductors, are concentric-lay- stranded, similar in construction and appearance to 1350 grade aluminum conductors. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201,6101 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201,6101 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.
Code Name | Stranding&wire diameter |
Approx Overall diameter |
Total area | Weight | Breaking Load | DC Resistance at 20 °c | Current Rating |
— | mm | mm | mm 2 | Kg/km | KN | Ohm/km | A |
Box | 7/1.85 | 5.55 | 18.8 | 51.4 | 5.55 | 1.748 | 93 |
Acacia | 7/2.08 | 6.24 | 23.9 | 64.9 | 7.02 | 1.3828 | 110 |
Almond | 7/2.34 | 7.02 | 30.1 | 82.2 | 8.88 | 1.0926 | 128 |
Cedar | 7/2.54 | 7.62 | 35.5 | 96.8 | 10.46 | 0.9273 | 132 |
Deodar | 7/2.77 | 8.31 | 42.2 | 115.2 | 12.44 | 0.7797 | 148 |
Fir | 7/2.95 | 8.85 | 47.8 | 130.6 | 14.11 | 0.6875 | 161 |
Hazel | 7/3.30 | 9.9 | 59.9 | 163.4 | 17.66 | 0.5494 | 184 |
Pine | 7/3.61 | 10.8 | 71.6 | 195.6 | 21.14 | 0.4591 | 204 |
Holly | 7/3.91 | 11.7 | 84.1 | 229.5 | 24.79 | 0.3913 | 222 |
Willow | 7/4.04 | 12.1 | 89.7 | 245 | 26.47 | 0.3665 | 233 |
Oak | 7/4.65 | 13.95 | 118.9 | 324.5 | 35.07 | 0.2767 | 272 |
Mulbery | 19/3.18 | 15.9 | 150.9 | 414.3 | 44.52 | 0.2192 | 319 |
Ash | 19/3.48 | 17.4 | 180.7 | 496.1 | 53.31 | 0.183 | 354 |
Elm | 19/3.76 | 18.8 | 211 | 579.2 | 62.24 | 0.1568 | 385 |
Poplar | 37/2.87 | 20.1 | 239.4 | 659.4 | 70.61 | 0.1387 | 414 |
Sycamore | 37/3.23 | 22.6 | 303.2 | 835.2 | 89.4 | 0.1095 | 487 |
Upas | 37/3.53 | 24.7 | 362.1 | 997.5 | 106.82 | 0.0917 | 527 |
Yew | 37/4.06 | 28.4 | 479 | 1319.6 | 141.31 | 0.0693 | 629 |
Totara | 37/4.14 | 29.42 | 498.1 | 1372.1 | 146.93 | 0.0666 | 640 |
Rubus | 61/3.50 | 31.5 | 586.9 | 1622 | 173.13 | 0.0567 | 716 |
Sorbus | 61/3.71 | 33.4 | 659.4 | 1822.5 | 194.53 | 0.0505 | 760 |
Araucaria | 61/4.14 | 37.3 | 821.1 | 2269.5 | 242.24 | 0.0406 | 842 |
Redwood | 61/4.56 | 41 | 996.2 | 2753.2 | 293.88 | 0.0334 | 920 |
▼Properties:
1. high strength |
▼Application of 95mm ABC Cable ( Aerial Bundled Cable )
New type of Aerial Bundle Cable for Power transmission, used for rebuilding of urban and forest regions, which can improve safety and reliance of electrified wire netting.
ABC Cable ( Aerial Bundled Cable ) | |||||||
SPEC. mm2 | Conductor Structure | Insulation Material | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Packing Meters per Drum | |
Phase (Compacted AL) | Neutral(Alloy) | ||||||
(No./mm) | Aluminum (No./mm) | ||||||
1x16+1x16 | 7/1.72 | 7x1.72 | XLPE (HDPE) | 1.2 | 12.5 | 110.1 | 250-4000m |
1x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 14.9 | 163.9 | 250-4000m | |
1x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 17.5 | 229.0 | 250-3500m | |
1x50+1x50 | 7/2.92 | 7/2.92 | 1.4 | 20.1 | 300.0 | 250-3000m | |
1x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 23.6 | 423.2 | 250-3000m | |
1x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 27.6 | 585.4 | 250-3000m | |
2x16+1x16 | 7/1.72 | 7/1.72 | 1.2 | 14.2 | 175.8 | 250-4000m | |
2x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 16.7 | 258.4 | 250-3500m | |
2x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 19.7 | 361.2 | 250-3500m | |
2x50+1x50 | 7/2.92 | 7/2.92 | 1.4 | 22.5 | 472.1 | 250-3000m | |
2x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 26.1 | 658.3 | 250-3000m | |
2x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 30.5 | 908.2 | 250-3000m | |
3x16+1x16 | 7/1.72 | 7/1.72 | 1.2 | 16.3 | 241.5 | 250-3500m | |
3x25+1x25 | 7/2.15 | 7/2.15 | 1.2 | 19.1 | 353.6 | 250-3500m | |
3x35+1x35 | 7/2.54 | 7/2.54 | 1.4 | 22.5 | 493.5 | 250-3000m | |
3x50+1x50 | 7/2.92 | 7/2.94 | 1.4 | 25.7 | 644.1 | 250-3000m | |
3x70+1x70 | 19/2.15 | 19/2.15 | 1.4 | 29.7 | 895.2 | 250-3000m | |
3x95+1x95 | 19/2.54 | 19/2.54 | 1.6 | 34.6 | 1233.5 | 250-3000m |
ABC Cable ( Aerial Bundled Cable ) | ||||||
SPEC. mm2 | Conductor Structure (Compacted AL) (No./mm) | Insulation Material | Insulation Thickness (mm) | Approx. Overall Diameter (mm) | Approx. Weight (kg/km) | Packing Meters per Drum |
2x16 | 7/1.72 | XLPE (HDPE) | 1.2 | 14.6 | 131.4 | 250-4000m |
2x25 | 7/2.15 | 1.2 | 16.8 | 189.0 | 250-4000m | |
2x35 | 7/2.54 | 1.4 | 19.8 | 264.5 | 250-3500m | |
2x50 | 7/2.92 | 1.4 | 22.6 | 344.1 | 250-3000m | |
2x70 | 19/2.15 | 1.4 | 25.6 | 470.0 | 250-3000m | |
2x95 | 19/2.54 | 1.6 | 29.8 | 645.5 | 250-3000m | |
3x16 | 7/1.72 | 1.2 | 15.7 | 197.1 | 250-4000m | |
3x25 | 7/2.15 | 1.2 | 18.1 | 283.5 | 250-3500m | |
3x35 | 7/2.54 | 1.4 | 21.3 | 396.7 | 250-3500m | |
3x50 | 7/2.92 | 1.4 | 24.3 | 516.2 | 250-3000m | |
3x70 | 19/2.15 | 1.4 | 27.6 | 705.1 | 250-3000m | |
3x95 | 19/2.54 | 1.6 | 32.1 | 968.2 | 250-3000m | |
4x16 | 7/1.72 | 1.2 | 17.6 | 262.9 | 250-3500m | |
4x25 | 7/2.15 | 1.2 | 20.3 | 378.0 | 250-3500m | |
4x35 | 7/2.54 | 1.4 | 23.9 | 528.9 | 250-3000m | |
4x50 | 7/2.92 | 1.4 | 27.3 | 688.3 | 250-3000m | |
4x70 | 19/2.15 | 1.4 | 30.9 | 940.1 | 250-3000m | |
4x95 | 19/2.54 | 1.6 | 36.0 | 1291.0 | 250-3000m |
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline
is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
The cable is supplied in wooden reels, corrugated boxes, and coils. Cable ends are sealed with BOPP self-adhesive
tape and non-hygroscopic sealing caps to protect the cable end from moisture. The required marking shall be printed
with a weather-proof material on the outsides of the drum according to customers' requirements.
▼Ordering Options:
For prompt quotation/supplies please make sure your inquiries and your orders are securing the following data :
1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material: PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.
If this all seems a little too technical for you, then why not get in touch with us. We look forward to assisting you in identifying the best products for your specific application and answering any questions you might have.