Model Name: | YJV | Rated Voltage: | 0.6/1KV |
---|---|---|---|
Size: | 1.5~630mm² | Nos. Of Core: | 2~5 |
Conductor Type: | Stranded Annealed Copper Class 2 | Sheath: | PVC |
Fire Performance: | IEC 60332-1 | Application: | Construction, Underground,Power Engineering, Rail Transit |
High Light: | YJV pvc insulated power cable,1.5 sqmm pvc insulated power cable,pvc 3 core 1.5 sq mm power cable |
Copper Conductor XLPE Insulation and PVC Jacket Power Cable
▼ Application:
1kV for Fixed installations such as distribution networks or industrial installations.
▼ Construction:
Core Conductor | annealed copper (stranded core) |
Popular sizes | 2~5core x1.5~630mm² |
Cable conductor | stranded annealed copper |
Insulation | XLPE |
Jacket | PVC |
Temperature rating | -25C up to +90℃ |
Voltage suitable | 0.6/1kV |
Fire performance | IEC 60332-1 |
Approval | QS in China |
▼ Advantage:
It has excellent thermal-mechanical properties, excellent electrical properties and chemical corrosion resistance, and also has the advantages of simple structure, light weight, and no drop limit for laying.
▼ Standards&Certificates:
IEC 60502-1
▼ Technical parameters:
1. Single Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
1×1.5 | 1 | 0.7 | 1.4 | 5.2 | 12.1 |
1×2.5 | 1 | 0.7 | 1.4 | 5.6 | 7.41 |
1×4 | 1 | 0.7 | 1.4 | 6.0 | 4.61 |
1×6 | 1 | 0.7 | 1.4 | 6.5 | 3.08 |
1×10 | 7 | 0.7 | 1.4 | 7.6 | 1.83 |
1×16 | 7 | 0.7 | 1.4 | 8.6 | 1.15 |
1×25 | 7 | 0.9 | 1.4 | 10.2 | 0.727 |
1×35 | 7 | 0.9 | 1.4 | 11.2 | 0.524 |
1×50 | 10 | 1.0 | 1.4 | 12.5 | 0.387 |
1×70 | 14 | 1.1 | 1.4 | 14.3 | 0.268 |
1×95 | 19 | 1.1 | 1.5 | 16.5 | 0.193 |
1×120 | 24 | 1.2 | 1.5 | 18.2 | 0.153 |
1×150 | 30 | 1.4 | 1.6 | 20.1 | 0.124 |
1×185 | 37 | 1.6 | 1.6 | 22.2 | 0.0991 |
1×240 | 48 | 1.7 | 1.7 | 24.9 | 0.0754 |
1×300 | 61 | 1.8 | 1.8 | 27.5 | 0.0601 |
1×400 | 61 | 2.0 | 1.9 | 30.8 | 0.0470 |
1×500 | 61 | 2.2 | 2.0 | 34.3 | 0.0366 |
1×630 | 61 | 2.4 | 2.2 | 41.3 | 0.0283 |
2. 2 Core&3 Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
2×1.5 | 1 | 0.7 | 1.8 | 8.9 | 12.1 |
2×2.5 | 1 | 0.7 | 1.8 | 9.7 | 7.41 |
2×4 | 1 | 0.7 | 1.8 | 10.6 | 4.61 |
2×6 | 1 | 0.7 | 1.8 | 11.6 | 3.08 |
2×10 | 7 | 0.7 | 1.8 | 13.8 | 1.83 |
2×16 | 7 | 0.7 | 1.8 | 15.7 | 1.15 |
2×25 | 7 | 0.9 | 1.8 | 18.9 | 0.727 |
2×35 | 7 | 0.9 | 1.8 | 20.9 | 0.524 |
2×50 | 10 | 1.0 | 1.8 | 24.6 | 0.387 |
2×70 | 14 | 1.1 | 1.8 | 28.2 | 0.268 |
2×95 | 19 | 1.1 | 1.9 | 32.4 | 0.193 |
2×120 | 24 | 1.2 | 2.0 | 35.8 | 0.153 |
2×150 | 30 | 1.4 | 2.2 | 39.6 | 0.124 |
2×185 | 37 | 1.6 | 2.3 | 44.0 | 0.0991 |
2×240 | 48 | 1.7 | 2.5 | 49.4 | 0.0754 |
2×300 | 61 | 1.8 | 2.6 | 54.3 | 0.0601 |
2×400 | 61 | 2.0 | 2.9 | 61.0 | 0.0470 |
2×500 | 61 | 2.2 | 3.1 | 68.4 | 0.0366 |
2×630 | 61 | 2.4 | 3.3 | 82.0 | 0.0283 |
3×1.5 | 1 | 0.7 | 1.8 | 9.4 | 12.1 |
3×2.5 | 1 | 0.7 | 1.8 | 10.2 | 7.41 |
3×4 | 1 | 0.7 | 1.8 | 11.2 | 4.61 |
3×6 | 1 | 0.7 | 1.8 | 12.2 | 3.08 |
3×10 | 7 | 0.7 | 1.8 | 14.6 | 1.83 |
3×16 | 7 | 0.7 | 1.8 | 16.7 | 1.15 |
3×25 | 7 | 0.9 | 1.8 | 20.1 | 0.727 |
3×35 | 7 | 0.9 | 1.8 | 22.3 | 0.524 |
3×50 | 10 | 1.0 | 1.8 | 26.2 | 0.387 |
3×70 | 14 | 1.1 | 1.9 | 30.3 | 0.268 |
3×95 | 19 | 1.1 | 2.0 | 34.6 | 0.193 |
3×120 | 24 | 1.2 | 2.1 | 38.5 | 0.153 |
3×150 | 30 | 1.4 | 2.3 | 42.6 | 0.124 |
3×185 | 37 | 1.6 | 2.4 | 47.3 | 0.0991 |
3×240 | 48 | 1.7 | 2.6 | 53.1 | 0.0754 |
3×300 | 61 | 1.8 | 2.7 | 58.2 | 0.0601 |
3×400 | 61 | 2.0 | 3.0 | 65.6 | 0.0470 |
3×500 | 61 | 2.2 | 3.2 | 73.5 | 0.0366 |
3×630 | 61 | 2.4 | 3.5 | 88.2 | 0.0283 |
3. 4 Core&5 Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
4×1.5 | 1 | 0.7 | 1.8 | 10.1 | 12.1 |
4×2.5 | 1 | 0.7 | 1.8 | 11.0 | 7.41 |
4×4 | 1 | 0.7 | 1.8 | 12.1 | 4.61 |
4×6 | 1 | 0.7 | 1.8 | 13.3 | 3.08 |
4×10 | 7 | 0.7 | 1.8 | 16.0 | 1.83 |
4×16 | 7 | 0.7 | 1.8 | 18.3 | 1.15 |
4×25 | 7 | 0.9 | 1.8 | 22.1 | 0.727 |
4×35 | 7 | 0.9 | 1.8 | 24.6 | 0.524 |
4×50 | 10 | 1.0 | 1.8 | 28.8 | 0.387 |
4×70 | 14 | 1.1 | 2.0 | 33.4 | 0.268 |
4×95 | 19 | 1.1 | 2.1 | 38.4 | 0.193 |
4×120 | 24 | 1.2 | 2.3 | 43.0 | 0.153 |
4×150 | 30 | 1.4 | 2.4 | 47.3 | 0.124 |
4×185 | 37 | 1.6 | 2.6 | 52.7 | 0.0991 |
4×240 | 48 | 1.7 | 2.8 | 59.0 | 0.0754 |
4×300 | 61 | 1.8 | 3.0 | 65.1 | 0.0601 |
4×400 | 61 | 2.0 | 3.3 | 73.3 | 0.0470 |
4×500 | 61 | 2.2 | 3.5 | 82.0 | 0.0366 |
4×630 | 61 | 2.4 | 3.8 | 98.6 | 0.0283 |
5×1.5 | 1 | 0.7 | 1.8 | 10.9 | 12.1 |
5×2.5 | 1 | 0.7 | 1.8 | 11.9 | 7.41 |
5×4 | 1 | 0.7 | 1.8 | 13.1 | 4.61 |
5×6 | 1 | 0.7 | 1.8 | 14.5 | 3.08 |
5×10 | 7 | 0.7 | 1.8 | 17.4 | 1.83 |
5×16 | 7 | 0.7 | 1.8 | 20.0 | 1.15 |
5×25 | 7 | 0.9 | 1.8 | 24.3 | 0.727 |
5×35 | 7 | 0.9 | 1.8 | 27.0 | 0.524 |
5×50 | 10 | 1.0 | 1.9 | 31.9 | 0.387 |
5×70 | 14 | 1.1 | 2.1 | 36.9 | 0.268 |
5×95 | 19 | 1.1 | 2.2 | 42.5 | 0.193 |
5×120 | 24 | 1.2 | 2.4 | 47.5 | 0.153 |
5×150 | 30 | 1.4 | 2.6 | 52.5 | 0.124 |
5×185 | 37 | 1.6 | 2.8 | 58.4 | 0.0991 |
5×240 | 48 | 1.7 | 3.0 | 65.5 | 0.0754 |
5×300 | 61 | 1.8 | 3.2 | 72.3 | 0.0601 |
5×400 | 61 | 2.0 | 3.5 | 81.2 | 0.0470 |
5×500 | 61 | 2.2 | 3.8 | 91.2 | 0.0366 |
5×630 | 61 | 2.4 | 4.1 | 109.5 | 0.0283 |
4. 3+1 Core & 3+2 Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
3×2.5+1×1.5 | 1 | 0.7 | 1.8 | 10.8 | 7.41 |
3×4+1×2.5 | 1 | 0.7 | 1.8 | 11.8 | 4.61 |
3×6+1×4 | 1 | 0.7 | 1.8 | 13.0 | 3.08 |
3×10+1×6 | 7 | 0.7 | 1.8 | 15.3 | 1.83 |
3×16+1×10 | 7 | 0.7 | 1.8 | 17.7 | 1.15 |
3×25+1×16 | 7 | 0.9 | 1.8 | 21.2 | 0.727 |
3×35+1×16 | 7 | 0.9 | 1.8 | 23.0 | 0.524 |
3×50+1×25 | 10 | 1.0 | 1.8 | 27.4 | 0.387 |
3×70+1×35 | 14 | 1.1 | 1.9 | 31.5 | 0.268 |
3×95+1×50 | 19 | 1.1 | 2.1 | 36.1 | 0.193 |
3×120+1×70 | 24 | 1.2 | 2.2 | 40.5 | 0.153 |
3×150+1×70 | 30 | 1.4 | 2.3 | 43.8 | 0.124 |
3×185+1×95 | 37 | 1.6 | 2.5 | 49.2 | 0.0991 |
3×240+1×120 | 48 | 1.7 | 2.6 | 55.0 | 0.0754 |
3×300+1×150 | 61 | 1.8 | 2.8 | 60.5 | 0.0601 |
3×400+1×185 | 61 | 2.0 | 3.1 | 68.1 | 0.0470 |
3×500+1×240 | 61 | 2.2 | 3.3 | 76.3 | 0.0366 |
3×630+1×300 | 61 | 2.4 | 3.6 | 90.1 | 0.0283 |
3×2.5+2×1.5 | 1 | 0.7 | 1.8 | 11.5 | 7.41 |
3×4+2×2.5 | 1 | 0.7 | 1.8 | 12.6 | 4.61 |
3×6+2×4 | 1 | 0.7 | 1.8 | 13.9 | 3.08 |
3×10+2×6 | 7 | 0.7 | 1.8 | 16.2 | 1.83 |
3×16+2×10 | 7 | 0.7 | 1.8 | 19.0 | 1.15 |
3×25+2×16 | 7 | 0.9 | 1.8 | 22.6 | 0.727 |
3×35+2×16 | 7 | 0.9 | 1.8 | 24.2 | 0.524 |
3×50+2×25 | 10 | 1.0 | 1.8 | 29.1 | 0.387 |
3×70+2×35 | 14 | 1.1 | 2.0 | 33.3 | 0.268 |
3×95+2×50 | 19 | 1.1 | 2.1 | 38.2 | 0.193 |
3×120+2×70 | 24 | 1.2 | 2.3 | 43.3 | 0.153 |
3×150+2×70 | 30 | 1.4 | 2.4 | 46.3 | 0.124 |
3×185+2×95 | 37 | 1.6 | 2.5 | 52.0 | 0.0991 |
3×240+2×120 | 48 | 1.7 | 2.7 | 58.1 | 0.0754 |
3×300+2×150 | 61 | 1.8 | 2.9 | 64.2 | 0.0601 |
3×400+2×185 | 61 | 2.0 | 3.2 | 72.1 | 0.0470 |
3×500+2×240 | 61 | 2.2 | 3.5 | 80.9 | 0.0366 |
3×630+2×300 | 61 | 2.4 | 3.8 | 94.7 | 0.0283 |
5. 4+1 Core
Cross section of conductor(mm²) | Conductor structure | Insulation Thickness(mm) | Copper sheath thickness(mm) | Approx.cable diameter(mm) | Max resistance of conductor at 20℃ (Ω/km) |
4×2.5+1×1.5 | 1 | 0.7 | 1.8 | 11.7 | 7.41 |
4×4+1×2.5 | 1 | 0.7 | 1.8 | 12.9 | 4.61 |
4×6+1×4 | 1 | 0.7 | 1.8 | 14.2 | 3.08 |
4×10+1×6 | 7 | 0.7 | 1.8 | 16.8 | 1.83 |
4×16+1×10 | 7 | 0.7 | 1.8 | 19.5 | 1.15 |
4×25+1×16 | 7 | 0.9 | 1.8 | 23.4 | 0.727 |
4×35+1×16 | 7 | 0.9 | 1.8 | 25.6 | 0.524 |
4×50+1×25 | 10 | 1.0 | 1.9 | 30.6 | 0.387 |
4×70+1×35 | 14 | 1.1 | 2.0 | 35.0 | 0.268 |
4×95+1×50 | 19 | 1.1 | 2.2 | 40.5 | 0.193 |
4×120+1×70 | 24 | 1.2 | 2.3 | 45.3 | 0.153 |
4×150+1×70 | 30 | 1.4 | 2.5 | 49.4 | 0.124 |
4×185+1×95 | 37 | 1.6 | 2.6 | 55.2 | 0.0991 |
4×240+1×120 | 48 | 1.7 | 2.9 | 61.9 | 0.0754 |
4×300+1×150 | 61 | 1.8 | 3.1 | 68.3 | 0.0601 |
4×400+1×185 | 61 | 2.0 | 3.4 | 76.7 | 0.0470 |
4×500+1×240 | 61 | 2.2 | 3.6 | 86.0 | 0.0366 |
4×630+1×300 | 61 | 2.4 | 3.9 | 102.1 | 0.0283 |
▼ Company information:
30 years of experience in R & D, production and sales of wire and cable.
Invest 200 million to build a modern industrial park, covering an area of 65000 square meters.
Annual revenue is about 500 million US dollars.
CNAS laboratory, more than 100 testing reports.
Products are widely used in real estate, municipal, industrial support, mobile communications etc
FAQ
* How to assure the quality of products?
1. Most of our products have certification.
2. Our Lab staff will test the material and check the process card before production.
3. The O.D tester is testing all the time during production, and the production line is always under control.
4. The product will be tested by Lab staff after production.
* Do you offer free samples or not?
1. If we have inventory about the sample you need and the total amount is not large, it's free.
2. If we don't have inventory, according to our company's rule, sample and freight costs need to be paid by your esteemed company. And we will return the sample cost to you when you place the first order with us. Thanks for your support.
* When I want customized products, how to do it?
We have professional equipment, technicians & skilled employees, OEM & customized service is welcome. Drawings or samples are required. Of course, the purchased quantity should meet our MOQ.