Place of Origin: | CHINA |
---|---|
Brand Name: | DONGJIAXIN |
Certification: | ISO9001/ISO14001/OHSAS18001/CCC/CE/RoH |
Model Number: | RVS cable-05 |
Minimum Order Quantity: | Negotiable |
Price: | Negotiable |
Packaging Details: | iron with wooden or wood or iron |
Delivery Time: | 7-15 working days |
Payment Terms: | L/C, T/T, Western Union, MoneyGram |
Supply Ability: | 100KM/WEEK |
Model Name: | RVS Cable-05 | Standard: | CE/CB/CCC |
---|---|---|---|
Size: | 1.5~630mm² | Voltage Rate: | 0.6/1KV |
Insulation: | PVC | Sheath: | Pvc , |
Application: | Construction,Industrial | ||
High Light: | 2*1.5 RVS copper xlpe cable,Pvc Insulated copper xlpe cable,xlpe copper cable |
Low voltage double PVC insulated rvs 2*1.5 electric cable wire for construction
1. Production Application
It is usually used for public address system / background music system wiring, fire protection system wiring. As the detection line of automatic fire alarm system, it is suitable for household appliances, small electric tools, instruments and power lighting. Double white core direct connection is adopted for light cable; red blue core is adopted for fire protection, alarm, etc
2. Company Certificates
ISO9001, ISO14001, OHSAS18001, CCC, CE, CB, RoHS, UL,China TOP 100 Enterprises in Cables industry, Guangdong TOP 20 Enterprises in Cables industry and others.
(mm2 ) |
Core structure no./diameter (mm) |
Average upper limit of O.D.(mm) |
2*0.5 | 28/0.15 | 6.0 |
2*0.75 | 42/0.15 | 6.2 |
2*1.0 | 56/0.15 | 6.6 |
2*1.5 | 84/0.15 | 7.2 |
2*2.5 | 140/0.15 | 8.2 |
2*4 | 220/0.15 | 9.5 |
2*6 | 190/0.20 | 11.6 |
1. The permissble long-term working temperature of the cable conductor: PVC insulated is 70 °C. During the cable laying, the ambient temperature must be above 0 °C.
2. The permissible bending radius in cable laying and installing.
a). For unarmoured cable, it shall not be less than 6 times of external diameter of cable.
b). For armoured or copper tape screened cable, it shall not be less than 12 times of the external diameter of cable.
c). For the flexible cable with screen layers, it shall not be less than 6 times of the external diameter of cable.
5. Type & Special
No×Area of conductor mm² |
Upper limit of average outer diameter mm |
Max conductor resistance at 20℃ |
Min insulation resistance at 70℃ Ω/km |
Recommended value of current carrying capacity A | Reference weight kg / km |
2*0.5 | 6.0 | 39.0 | 0.016 | 9 | 22 |
2*0.75 | 6.2 | 26.0 | 0.014 | 12 | 29 |
2*1 | 6.6 | 19.5 | 0.013 | 14 | 34 |
2*1.5 | 7.2 | 13.3 | 0.012 | 18 | 46 |
2*2.5 | 8.2 | 7.98 | 0.0095 | 25 | 66 |
2*4 | 9.5 | 4.95 | 0.0079 | 33 | 96 |
2*6 | 11.6 | 3.30 | 0.0081 | 42 | 145 |
Quantity(box) | 10 | 100 |
EST.time(day) | 3-5 | 5-15 |
We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline
is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
The cable is supplied in wooden reels, corrugated boxes, and coils. Cable ends are sealed with BOPP self-adhesive
tape and non-hygroscopic sealing caps to protect the cable end from moisture. The required marking shall be printed
with a weather-proof material on the outsides of the drum according to customers' requirements.
▼ Cable Drum Data:
CABLE DRUMS | D1=Flange Diameter(mm) | W=Useful Width (mm) | D2=Barrel Diameter(mm) |
![]() |
1000 | 700 | 500 |
1100 | 700 | 550 | |
1200 | 700 | 600 | |
1400 | 750 | 710 | |
1600 | 900 | 900 | |
1800 | 1120 | 1000 | |
2400 | 1150 | 1300 |
▼Ordering Options:
For prompt quotation/supplies please make sure your inquiries and your orders are securing the following data :
1 International or Special Standard. (Alternatively, the precise usage of the cable.)
2 Rated voltage.
3 Copper or Aluminium conductors.
4 Size of each conductor.
5 Insulation material: PVC XLPE or others.
6 Number and identification of conductors.
7 Other requirements.
8 Packing.
9 Required delivery time.
10 Required validity.
If this all seems a little too technical for you, then why not get in touch with us. We look forward to assisting you in identifying the best products for your specific application and answering any questions you might have.